{"product_id":"44278","title":"Blue Sea ML-ACR Automatic Charging Relay with Manual Control 12vDC 500A","description":"\u003cp\u003e\u003cb\u003eBlue Sea Systems ML-ACR Automatic Charging Relay with Manual Control - 12V DC 500A\u003c\/b\u003e\u003c\/p\u003eModel: 7622-BSS\u003cbr\u003e\u003cul class=\"wtul\"\u003e\n\u003cli\u003eAutomatically manages the charging of two large battery banks\u003c\/li\u003e\n\u003cli\u003eAllows paralleling of battery banks for emergency starting\u003c\/li\u003e\n\u003cli\u003e500 Ampere continuous rating to support high-output alternators\u003c\/li\u003e\n\u003cli\u003eMagnetic Latch (ML)—ACR draws very low current (\u0026lt;40mA to monitor terminal voltage) in the \"ON\" or \"OFF\" states, and draws moderate current for very short time when changing state\u003c\/li\u003e\n\u003cli\u003eDual sensing—senses charge on both battery banks\u003c\/li\u003e\n\u003cli\u003eStart Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics\u003c\/li\u003e\n\u003cli\u003eEngine Isolation (EI)—can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output\u003c\/li\u003e\n\u003cli\u003eSenses charging on two battery banks\u003c\/li\u003e\n\u003cli\u003eManual control switch provides an added level of safety allowing control with or without power, and offering LOCK OFF capability for servicing\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine\u003c\/p\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003cbr\u003e\u003ctable style=\"border-collapse: collapse\" width=\"95%\" border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eControl Circuit Connection\u003c\/td\u003e\n\u003ctd\u003eTinned Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eManual Control\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eEngine Isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eStart Assist\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eStart Isolation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eAmperage Operating Current\u003c\/td\u003e\n\u003ctd\u003e13mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eAmperage Operating Current when changing state\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;7.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eTerminal Stud Torque\u003c\/td\u003e\n\u003ctd\u003e140 in-lb (15.82 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eContinuous Rating\u003c\/td\u003e\n\u003ctd\u003e500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eIntermittent Rating\u003c\/td\u003e\n\u003ctd\u003e700A (5 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eCranking Rating 30 sec\u003c\/td\u003e\n\u003ctd\u003e1450A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10° C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e60° C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eCable Size to Meet Ratings\u003c\/td\u003e\n\u003ctd\u003e4\/0 AWG x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eLive Current Switching\u003c\/td\u003e\n\u003ctd\u003e300A @ 12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eStud Material\u003c\/td\u003e\n\u003ctd\u003eTinned Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eSwitching Cycles\u003c\/td\u003e\n\u003ctd\u003e100000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eTerminal Ring Diameter Clearance\u003c\/td\u003e\n\u003ctd\u003eTerminal Ring Diameter Clearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eTerminal Stud Length\u003c\/td\u003e\n\u003ctd\u003e1.50in (38.1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eTerminal Stud Size\u003c\/td\u003e\n\u003ctd\u003e3\/8\" - 16 (M10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"175px\"\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e20 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cbr\u003e\u003cb\u003eWhat's in the Box:\u003c\/b\u003e\u003cul class=\"wtul\"\u003e\n\u003cli\u003eML-ACR Automatic Charging Relay with manual Control  12v\u003c\/li\u003e\n\u003cli\u003eSPDT Remote Control Contura Switch - ON-OFF-ON\u003c\/li\u003e\n\u003cbr\u003e\u003cbr\u003eWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.\u003cp\u003eBrand: Blue Sea Systems\u003c\/p\u003e\n\u003cp\u003eUPC: 632085076221\u003c\/p\u003e\n\u003cp\u003eModel Number: 7622-BSS\u003c\/p\u003e\n\u003cp\u003eWeight: 2.060000\u003c\/p\u003e\n\u003c\/ul\u003e","brand":"Blue Sea Systems","offers":[{"title":"Default Title","offer_id":45935201222831,"sku":"wt-BSS7622","price":363.89,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0350\/0497\/3196\/files\/BSS7622.jpg?v=1759567518","url":"https:\/\/www.dbmarinesupplies.com\/en-ca\/products\/44278","provider":"DB Marine Supplies","version":"1.0","type":"link"}